Check for Proper Metadata Verification and Saves
DuringnormaloperationUnity™MediaNetworkwillwriteitstodiscMetadatacontinuouslywith20second
pausesbetweenMetadatasaves.ThelastverificationandsavetimescanbefoundontheMetadatatabof
theMonitorTool.IfyoucannotseetheMetadataStatustab,usetheTabnavigationbuttonstoscroll
through
thetabs.
Fig.5‐MetadataStatusVerifyandSavetimes
BecausetheMetadataisverifiedandsavedwith20secondpauses,theVerifyandSavetimesshouldbewithin
afewminutesofcurrenttime.Asthesystemfillsup,themetadatagrowsandtakeslongertosave,resulting
inslightlylongertimelagssincethelastsuccessfulVerify/
Save.
Ifthemetadataappearsnottohavebeenupdatedforsometime(severalhoursforexample)thencontact
AvidCustomerSuccessforassistance.
NOTE: Examiningthetim eanddatestampof thethreemetadata filesintheD:\AVIDONLYfolderwill
notprovideanaccurateindicationofthelastmetadata
save.TheFileManagerservicewrites
directlyintothesefilesonahardwarelevelandtheWindowsdatestampisnotupdateduring
thesewrites.